Section 1 • For Students & Attendees

How to Tap & Health Break Rules

Quick visual rules you can share or post at the entrance table.

1 Tap Your ID Card

  • AHold your RFID card steady on the reader until the screen flashes green with your name.
  • BFirst time? Tell the desk operator your Student ID—binding takes 3 seconds and stays saved permanently.
  • CForgot your card? Give your Student ID number for Manual Input.

2 15-Min Health Break

  • 1Tap 1 (Going Out): Starts your 15-minute live countdown timer.
  • 2Tap 2 (Returning In): Stops the timer—return within 15 minutes to stay present.
  • !Returning past 15 minutes (or not returning) automatically marks that session ABSENT.

3 5% Simultaneous Limit

During Recollection events, only 5% of the uploaded roster may be out on a health break at the same time (e.g., 100 students → max 5 out).

LIMIT REACHED? Wait until a student returns and taps back in—returning students are never blocked.
AM & PM are separate: An AM break penalty does not block your PM attendance.
Section 2 • For Station Operators & Staff

Running the Live Attendance Terminal

Everything on the main screen—switching sessions, handling breaks, binding new cards, and logging walk-ins.

1. Switch Modes & Monitor Health Breaks

  1. 1Under PROCESS OF ATTENDANCE, check Time-in, Time-out, or Health Break (15m) (visible only in RECOLLECTION mode).
  2. 2Under TIMEZONE, pick AM or PM. Mode changes sync instantly across all connected stations.
  3. 3Watch the amber Active Health Breaks bar: chips turn green (>3m left), yellow (≤3m left), or red (auto-absent >15m).
  4. 4The top-right badge shows live capacity (2 / 5 OUT (5% MAX)) and turns red at capacity.
Strict Roster Check: Only students in the active roster can scan. Non-roster cards and Admin badges are automatically rejected from attendance.
RECOLLECTION Mode — live 15-minute countdown chips, 5% MAX capacity counter, and automatic ABSENT (Break >15m) flags.

2. Bind a New Card (First-Time Student)

  1. 1Confirm Controlling Station (bottom-right) matches your desk's scanner ID (e.g., 1 or 2).
  2. 2Under BIND UNREGISTERED RFID, type the Student ID and click BIND CARD.
  3. 3Have the student tap their card once—it saves permanently and logs their attendance right away.

3. Manual Input & Unlisted Walk-Ins

  1. 1Forgot Card: Type the Student ID in MANUAL INPUT and press CONFIRM.
  2. 2Not on Roster: Click + Add Unlisted Student, enter ID, Full Name, Course, Department, and optional Class Code.
  3. 3Optional: Click Tap Card to capture their RFID badge during registration, then click Save & Log.
Walk-in students can be registered on the spot without editing the master roster CSV.

4. Scanner Status Light Reference

Bottom-right RFID Scanner Status Indicator
State Indicator Meaning What to Do
Connected Green Dot Reader is active and sending heartbeats for your Controlling Station. Ready to scan cards and bind tags.
Disconnected Red Dot Scanner unplugged, bridge window closed, or wrong Station ID selected. Check USB cable, confirm start_client.bat is open, and match Station ID.
Checking Grey Dot You just typed a new Controlling Station number and the UI is checking it. Wait 2–3 seconds for status to turn green.
Section 3 • For Administrators

Admin Console Playbook

Manage events, rosters, bulk RFID uploads, user name fixes, official VPMI Excel/ZIP reports, and security.

Unlock Admin Console: Click ADMIN CONSOLE, then enter the Admin PIN (default 1234) OR tap any authorized Admin RFID badge.
5-Card Control Center: Events (1), Roster & RFIDs (2), Reports & Reset (3), Diagnostics (4), and PIN / Admin Badges (5).

1. Event Management — MASS vs. RECOLLECTION

Click EDIT / CREATE EVENT to set event details, then switch modes anytime
Feature MASS Mode RECOLLECTION Mode
Attendance Columns Standard AM/PM Time-In & Time-Out AM/PM Time-In/Out + 15-min AM/PM Health Breaks
5% Simultaneous Cap Not active Active — blocks Tap 1 when 5% of roster is already out
Overdue Break (>15m) Not applicable Auto-marks that session ABSENT and blocks session Time-Out

2. Upload Master Class Roster (.csv)

Card 2 → UPLOAD ROSTER CSV
  1. 1Click Download Roster Template (.csv) or prepare your CSV with ID_NUMBER and NAME.
  2. 2Choose your CSV, authorize with Admin PIN or Admin Badge, and click Upload.
  3. 3Previously bound RFID tags from the permanent registry are restored automatically.

3. Bulk Upload RFID List (.csv or .xlsx)

Card 2 → UPLOAD RFID LIST
  1. 1Already have a list of scanned/registered RFIDs? Upload a .csv or .xlsx file instead of binding one by one.
  2. 2Only ID Number and RFID Tag / UID are required (Full Name, Department, and Course are optional).
  3. 3Tags save permanently and link to active roster students immediately so they can scan right away.

4. Edit Registered Student Names

  1. 1Click MANAGE / EDIT USERS in Card 2 and search by Name, ID #, Course, or UID.
  2. 2Click EDIT NAME, fix any spelling mistake in the yellow bar, and click SAVE.
  3. 3Student ID # and RFID Tag stay untouched; the corrected name updates across the roster, live logs, and Excel reports.

5. Reports, Session Reset & Security

  • ADOWNLOAD REPORTS (ZIP): Downloads official VPMI EOMS-FM-MIN-008 Excel workbooks split by Class Code + Master Summary.
  • BRESET SESSION DATA: Clears today's attendance for the next event. Permanent RFID tags are never wiped.
  • CADMIN SECURITY (Card 5): Change your Admin PIN anytime and authorize or revoke Admin RFID badges with one tap.
Fix typos in student names anytime—ID Numbers and bound RFID tags are locked and preserved.
Ready-to-Use Files • One-Click Downloads

Upload CSV Templates

Download a template, replace the 3 example rows with your real class list, save, and upload in Admin Console Card 2.

Master Roster

Roster Template

Upload via UPLOAD ROSTER CSV. Sets the active student list and the 5% Recollection break cap.

Columns: ID_NUMBER, NAME, DEPARTMENT, PROGRAM, CLASS_CODE
Download roster_template.csv
Bulk RFID (Full)

RFID List — Full

Upload via UPLOAD RFID LIST when importing RFIDs along with student names, departments, and courses.

Columns: ID Number, Full Name, Department, Course, RFID Tag
Download rfid_list_template.csv
Bulk RFID (Quick)

RFID List — 2-Column

Upload via UPLOAD RFID LIST when your roster is already uploaded. Preserves existing names automatically.

Columns: ID Number, RFID Tag
Download 2-Col Template (.csv)
3 Quick Excel Tips Before Uploading: (1) Delete the 3 sample rows (2240001–2240003) before uploading. (2) Format the ID Number and RFID Tag columns as Text so Excel does not drop leading zeros or convert long tags into 1.23E+15. (3) Keep Row 1 headers intact; save Master Rosters as .csv (RFID Lists accept both .csv and .xlsx).
Section 4 • Hardware & IT Setup (Web / Docker)

Server, Client Scanners & Arduino Wiring

Quick deployment reference for setting up the main Docker server, extra client scanning laptops, and RFID hardware.

1. Main Server PC (Docker + Station 1)

  1. 1First-time Windows setup: run install_server_dependencies.bat, restart, then open Docker Desktop.
  2. 2Plug in Scanner #1 and start the stack (keep the terminal window open while scanning):
start_server.bat
./start_server.sh

Dashboard URL: http://localhost (this PC) or http://<server-ip> (other devices). Allow Firewall ports 80 and 3001.

2. Extra Client Scanners (Station 2, 3, …)

  1. 1Client PCs do not need Docker. Run install_client_dependencies.bat once (installs Python + serial libraries).
  2. 2Plug in the USB RFID scanner, launch the client script, and enter the Server IP + a unique Station ID (2, 3, etc.):
start_client.bat
python bridge/serial_reader.py 192.168.1.50 2

On that laptop's browser, set Controlling Station to the same Station ID (e.g., 2).

3. Arduino Uno / Nano + MFRC522 RFID Wiring

HARDWARE WARNING: Connect MFRC522 3.3V strictly to Arduino 3.3V—connecting to 5V can permanently damage the RFID module.
MFRC522 SPI Wiring (9600 baud • Outputs UID:XXXXXXXX)
MFRC522 Pin Arduino Uno / Nano Pin Notes
SDA (SS)Pin 10Chip select (SS_PIN)
SCKPin 13SPI clock
MOSIPin 11Master Out Slave In
MISOPin 12Master In Slave Out
RSTPin 9Reset pin (RST_PIN)
GNDGNDCommon ground
3.3V3.3V3.3V ONLY — never 5V
IRQUnconnectedLeave empty

4. Quick Troubleshooting & FAQ

Scanner light stays RED even though the Arduino is plugged in

Check that Controlling Station on the bottom-right matches the Station ID running in your terminal (Server is 1; clients are 2, 3, etc.).

Also confirm the start_server.bat or start_client.bat window is still open and didn't lose connection.

Other laptops cannot open the dashboard or say "Connection refused"

Verify both laptops are on the exact same Wi-Fi / LAN network and use the Server IP printed by start_server.bat (e.g., http://192.168.1.50).

Allow incoming TCP ports 80 (web dashboard) and 3001 (live scanner updates) in Windows Defender Firewall on the Server PC.

A student tapped their card and got "Not in Active Roster" or "Admin RFID"

LUMENS strictly restricts attendance scans to students in the currently uploaded roster. Upload the correct class roster CSV first, or register a walk-in student via + Add Unlisted Student.

Admin RFID badges cannot be used to log student attendance unless the badge belongs to an active roster student.

Student gets "Health Break limit reached (5%)" during Recollection

The active break cap is automatically set to 5% of the uploaded roster (minimum 1). Wait until any student currently on break returns and taps back in—returning taps are never blocked, and overdue (>15m) breaks free their slot automatically.

Will resetting session data or restarting Docker erase registered RFID cards?

No. Stopping Docker or clicking RESET SESSION DATA never deletes the permanent rfid_registry. Every bound tag is also mirrored to backend/backups/rfid_bindings_backup.csv and can be downloaded anytime via DOWNLOAD RFID BACKUP or re-uploaded via UPLOAD RFID LIST.

"Docker failed" on startup or forgot the Admin PIN

Open Docker Desktop manually and wait until the bottom-left engine icon turns green before double-clicking start_server.bat.

Default Admin PIN is 1234 (configurable in docker-compose.yml or Card 5 of the Admin Console).

New • Official Standalone Edition (v2.3.0)

Meet LUMENS Desktop — Zero Docker Required

Prefer a single native app instead of Docker Desktop and Python scripts? The official LUMENS Desktop edition gives you the exact same interface with built-in desktop hardware and offline superpowers.

  • One-Click Installers: Native Windows .msi / .exe and Linux .AppImage / .deb
  • Built-In USB Reader: Direct Arduino serial connection—no Python bridge needed
  • Server Wi-Fi Hotspot: Run multi-station LAN attendance even with zero venue Wi-Fi
  • Auto 4-Sheet Excel Backups: Automatic verified SQLite + Excel snapshots on schedule
Official LUMENS Desktop — native Server/Client wizard with Wi-Fi Hotspot, USB Reader, and Automatic Backups.